TLC (Thin Layer Chromatography)

 

TLC is a simple, quick, and inexpensive procedure that gives the chemist a quick answer as to how many components are in a mixture. TLC is also used to support the identity of a compound in a mixture when the Rf of a compound is compared with the Rf of a known compound (preferrably both run on the same TLC plate).

Lipid Analysis by TLC Protocol 1

 

Handle the plates carefully. Don?t leave any fingerprints. These will be shown after exposing to I2 vapour.

1. Using the template provided, mark the plates with a sharp pencil.

 

2. Line the chamber with chromatography paper. Prepare 202 ml of solvent system (Hexane:Ether:Acetic acid 60:40:1) in a 500 ml Erlenmeyer flask. Mix and pour ~150 ml into the chamber. Cover and let the chamber saturate while loading the plates.

 

3. With a 10 ul capillary pipette, spot 1-2 ul of phospholipids standard onto the TLC plate, as shown. Make sure the spot remains smaller than 4 mm in diameter. Move on to the other standards. After the spots have dried, repeat loading each standards until you have loaded approx. 10 ul each. Also, load 10 ul of your lipid extract on one spot, and then the remainder of the extract as a line (i.e., a series of spots).

 

4. Let dry the spots. Make sure that the loading area is above the solvent. Place the plates in the chamber to develop.

 

5. Immediately close the cover and let run for approximately 30 min, until the solvent front has reached the upper line.

 

6. Remove the plate and leave to dry in the rack in the fume hood. Discard the solvent in the waste container provided, remove the chromatography paper and leave in the chamber. Leave the chamber in the fume hood to dry.
 

7. Now place the plate in the iodine tank in the fume hood. You will see the lipids as yellow spots after about 5 min or so.

 

8. Mark the edges of the spots with a pencil. Make a tracing on onion skin paper for a record.

9. Scrap off lipid fractions as shown, place in weighing paper, fold and roll to grind the clumps.

 

10. Meanwhile prepare columns to elute the lipids from silica gel. To do this insert a small amount of glass wool into a pasteur pipette, label the pipette and leave on the stand provided.

 

11. Carefully transfer the silica gel having different lipids into appropriate columns. Keep 7 ml glass vials beneath the columns.

 

12. Drip 1 ml of chloroform into each column except for the phospholipid and monoacylglycerol columns. To the latter, add >1 ml of 100 % methanol.

13. Shake the vials well. Place them in the fume hood evaporating set-up and evaporate off the solvent under a stream of N2. (Ask the instructor before using the N2 tank).

 

14. Store the dry lipids under N2.

 

15. Label and leave the separated lipid in the -20 C freezer until

transmethylation (day 2).

 

How Does TLC work?

TLC Procedure, Educational Movie, Troubleshooting and more.

 

Protocol 2. Brad's TLC protocol

 

Protocol 3. Immunostaining Thin Layer Chromatography of Glycolipids

 

Protocol 4. TLC PI3K Assay

 

Protocol 5. Lipid Analysis: Thin Layer Chromatography

 

Protocol 6. Thin Layer Chromatography

 

 
 
Contact Us: ebiotek.com@gmail.com {Copyright (C) 2008 E-BioTek.Com. All Rights Reserved}
Google
 
E-BioTek.Com
 

Protocols / Metabolish and Chromatographies

Metabolism and Chromatographies

GC/MS Background

Glucose metabolism and its related protocols
PAS staining
Polysaccharide sequencing
Deoxyribose procedure
Ribose metabolism analysis
Lactate cleanup and derivative
Amino acids
Fatty acids

Lipid Protocols

Cholesterol
Bile acids
Urea procedure
Choline Incorporation Assay
Isotope Ratio Mass Spectrometer (IRMS)
Liquid chromatography / mass spectrometer (LC/MS)
Proteomics
HPLC protocols 
TLC
NMR protocols and tutorials

Molecular labeling 

||WebHomeHome | Protocols | Bio Video | Resource | Medicine | Forum ||